Settings Menu: iSx Pump Cntrl
From this menu setting you can specify the IntelliFlo VS or VF pump speed (RPM, GPM) in step increments,
for the assigned iS4 or iS10 button using the “Pump Incrs” or “Pump Decrs” circuit (see page 44 and 45). For
example, the “Pump Incrs” and “Pump Decrs” circuit can be assigned to any two iS10 buttons. Each press
of the assigned “increase” button will increase the pump speed in specific speed increments, as specified in the
“iSx Pump Cntrl” menu setting. Speed increments are set from 10 to 250 RPM or 1 to 10 GPM.
Assign iSx Pump Cntrl
Before configuring the pump step speed, be sure to specify the IntelliFlo pump number and type in the
IntelliFlo menu (“Pump #1, Pump #2,” Pump Type), see page 32.
To assign a pump step speed:
Up/Down buttons: Select the “Pump Number” as specified in the IntelliFlo menu
(see page 32).
Right buttons: Select the pump “Step” speed.
Up/Down buttons: Adjust the “Step” pump speed. Settings are:
- IntelliFlo VS, 10 to 250 RPM
- IntelliFlo VF 1 to 10 GPM.
Press the Menu button to save the settings and to return to the Settings menu
options. Press the button twice to return to the main screen.
MENU SETTINGS iSx PUMP CNTRL ASSIGN IS10 & 4QT4
Getting There
Assign iS10 & 4
Pump Controls
Pump Number: 1
Step RPM: 010
Assign iS10 & 4
Pump Controls
Pump Number: 1
Step GPM: 001