Compool/EasyTouch Pool and Spa Control System Upgrade Installation and Users Guide
IntelliFlo VF pump
To access the IntelliFlo VF menu:
Up or Down button: Choose Pump #1 or Pump #2
Right button: Select Pump #1 to assign as IntelliFlo VF or IntelliFlo VS.
Right button: Select Pump Type.
Up/Down buttons: Choose Select VF (IntelliFlo VF).
Menu button: Press the menu button to save selection and go to the IntelliFlo VS
menu settings.
Press the Down button: Choose
FILT. CIRCUIT. Press the Right button to
access the filter circuits settings. Press the Up/Down buttons to assign the circuit:
None, Spa, Pool, Aux 1-7, Feature 1-8, Aux Extra (only if Solar is not
selected, see page 25 and 42), Heater, Pool Heater, Spa Heater, Freeze,
Pool/Spa, Solar/Heat. “Aux Extra” is only available if the Solar output (J17) plug on
the EasyTouch motherboard is not being used for solar equipment. Press the MENU
button to save and exit to Pump menus.
Press Down/Up button to select FLOWS. Press the Right button to access
settings: Press the Up/Down buttons to set GPM and CIRCUIT for circuit 1 of 8.
After circuit selection is finished, press the Up arrow button and go to the next
circuit page settings (2/8) and repeat setup. Up to eight (8) circuits can be assigned.
When finished , Press the MENU button to save and exit to Pump menus.
Press Down/Up button to select
FILTERING, PRIMING, BACKWASH,
VACUUM, or STATUS. Press the Right button to access settings: Press the
Up/Down buttons to set parameters. See IntelliFlo VF parameter descriptions
below:
Filtering -Pool Size/Gallons: 0 - 255 (Kgals) - Turnovers per day: (1 - 8)
Filtering Manual Filter GPM: (15 - 130) Default 30 GPM: Manual Filter sets the flow at which
the pump will run if it is turned on manually. The IntelliFlo pump will only run in the 'Filter'
mode during the programmed times. For example, if the pump is programmed (start/stop
times) for the pool circuit to run from 8:00 AM to 4:00 PM everyday. This program or programs
are used by IntelliFlo to calculate at what speed it must run given those ‘ON’ times to achieve
the turnover(s) for that sized pool for the basic filter mode.
Priming - Max Prime Flow GPM: (15 - 130) Default 55 GPM: Every time the pump starts this
parameter will negotiate the maximum flow of the pump. If the flow is too high, equipment
damage can occur. If the flow is to low the pump will not prime. This “flow” is system
dependent and may require adjustment. The pump will never flow more than this parameter is
set to, however, it is common for the pump to ramp up and down quickly while priming.
Always try to keep this flow as low as possible for cost savings and safety.
Priming - Max Prime Time: (1 - 15 minutes) Default 15 min.: Use this parameter to set the
time that you want IntelliFlo try and prime before it reports an error. Remember that the
IntelliFlo will attain prime every time it starts and goes through this cycle. The IntelliFlo
mechanical seal can withstand about 15 minutes before severe damage occurs. The lower
the time the quicker you will get a priming error if the system is difficult to prime. A well
plumbed pool without having the strainer removed should prime in less than 30 seconds. If
the strainer has been removed for cleaning and a substantial amount of air is in the system it
should prime in about 60 to 90 seconds on the average, however, all systems will be
different.
Priming - System Prime Time: (0 - 5 minutes) Default 0 min.: Remember that the average
unit will prime in a short period of time because the IntelliFlo has the ability to monitor itself to
make sure it is primed. “System Prime Time” is for systems that require high flows that priming
flow can provide but it is deemed that more time is needed to fully relieve all the air. The
builder can program a pre determined amount of time, up to 5 minutes, to aid in relieving the
air from difficult filters or complex vertical plumbing. The “System PrimeTime” should only be
used where large air traps become problems within the system. The display will inform the
user when this is engaged and when it is finished during the priming cycle at each start up
cycle.
MENU SETTINGS INTELLIFLO PUMP # 1
Getting There
Pump #1 1/8
GPM : 30
Circuit:
[ AUX 1 ]
Pump #1 Type
Type: VF
Pump Type
Filt. Cir
Flow
Filtering
Pump #1
Pump #2
Pump Filtering
Size : 1500
Turns : 2
Man Filt: 0
iS4/iS10 pump
speed control:
IntelliFlo pump
speed can be
increased or
decreased in
increments from an
iS4 or iS10 spa-side
remote. See “iSx
Pump Control” in
the “Settings” menu
(page 46).
Pump Priming
Max Flow : 55
Max Time : 5
Sys time : 0
Pump #1 1/8
GPM : 30
Circuit:
[ AUX 1 ]